© 2015 Datalink Systems, Inc.
www.datalinksystemsinc.com
15.0 Programming Settings from DataGate
The DataGate server can send and receive individual i50 settings using the Remote Config button on
the Asset Properties window (Modems tab). Each setting is referenced by ID, with integer and string
values in separate lists. Many of these settings are crucial to the correct operation of the device, so
take care when making changes. These changes can also be made by an administrator via the
WebGate interface.
15.1 Integer Values
Update clock using GPS (1=Yes 0=No)
Alarm state. Bits 7-5 are response state. Bits 4-1 are alarm state. Bit 0 indicates
geofence on
Cellular IP address (also uses I_IP2-I_IP4). Range=0-255
PORTA (Program/COM1/WiFi) Port Setting. See note at bottom for values
PORTB (COM2) Port Setting. See note at bottom for values
PORTC (GPRS) Port Setting. See note at bottom for values
PORTD (Iridium) Port Setting. See note at bottom for values
PORTF (COM3) Port Setting. See note at bottom for values
PDT COM Speed. See note at bottom for values
System Events (Firmware >= 4.77). Bit 2=Errors. Bit 1=Power Down. Bit
0=Power Up
Unit ID (also uses I_ID2 and I_ID3). Range=0-255
Input 1 Setting. See note at bottom for values
Input 2 Setting. See note at bottom for values
Input 3 Setting. See note at bottom for values
Input 4 Setting. See note at bottom for values
Send events when Input 1 changes. Bit 0=Low. Bit 1=High
Send events when Input 2 changes. Bit 0=Low. Bit 1=High
Send events when Input 3 changes. Bit 0=Low. Bit 1=High
Send events when Input 4 changes. Bit 0=Low. Bit 1=High
Input 1 polarity (0=Active Low 1=Active High)
Input 2 polarity (0=Active Low 1=Active High)
Input 3 polarity (0=Active Low 1=Active High)
Input 4 polarity (0=Active Low 1=Active High)
Send events when IGN changes. Bit 0=Low. Bit 1=High
Output 1 Setting. See note at bottom for values
Output 2 Setting. See note at bottom for values
Output 3 Setting. See note at bottom for values
Output 1 polarity (0=Low 1=High)
Output 2 polarity (0=Low 1=High)
Output 3 polarity (0=Low 1=High)