15.0 Programming Settings from DataGate
The DataGate server can send and receive individual i50 settings using the Remote Config button on
the Asset Properties window (Modems tab). Each setting is referenced by ID, with integer and string
values in separate lists. Many of these settings are crucial to the correct operation of the device, so
take care when making changes. These changes can also be made by an administrator via the
WebGate interface.
15.1 Integer Values
ID
Name
Description
Default
0
I_UPDATE
Update clock using GPS (1=Yes 0=No)
1
1
I_ALARMSTATE
Alarm state. Bits 7-5 are response state. Bits 4-1 are alarm state. Bit 0 indicates
geofence on
0
2
I_IP1
Cellular IP address (also uses I_IP2-I_IP4). Range=0-255
-
3
I_IP2
-
4
I_IP3
"
-
5
I_IP4
"
-
6
I_PORTA
PORTA (Program/COM1/WiFi) Port Setting. See note at bottom for values
0
7
I_PORTB
PORTB (COM2) Port Setting. See note at bottom for values
0
8
I_PORTC
PORTC (GPRS) Port Setting. See note at bottom for values
0
9
I_PORTD
PORTD (Iridium) Port Setting. See note at bottom for values
0
10
I_PORTF
PORTF (COM3) Port Setting. See note at bottom for values
0
11
I_SATSPEED
PDT COM Speed. See note at bottom for values
7
12
I_EVENTS
System Events (Firmware >= 4.77). Bit 2=Errors. Bit 1=Power Down. Bit
0=Power Up
7
13
I_ID1
Unit ID (also uses I_ID2 and I_ID3). Range=0-255
255
14
I_ID2
"
255
15
I_ID3
"
255
16
I_INPUT1
Input 1 Setting. See note at bottom for values
0
17
I_INPUT2
Input 2 Setting. See note at bottom for values
0
18
I_INPUT3
Input 3 Setting. See note at bottom for values
0
19
I_INPUT4
Input 4 Setting. See note at bottom for values
0
20
I_USEINPUT1
Send events when Input 1 changes. Bit 0=Low. Bit 1=High
0
21
I_USEINPUT2
Send events when Input 2 changes. Bit 0=Low. Bit 1=High
0
22
I_USEINPUT3
Send events when Input 3 changes. Bit 0=Low. Bit 1=High
0
23
I_USEINPUT4
Send events when Input 4 changes. Bit 0=Low. Bit 1=High
0
24
I_INPOLARITY1
Input 1 polarity (0=Active Low 1=Active High)
0
25
I_INPOLARITY2
Input 2 polarity (0=Active Low 1=Active High)
0
26
I_INPOLARITT3
Input 3 polarity (0=Active Low 1=Active High)
0
27
I_INPOLARITY4
Input 4 polarity (0=Active Low 1=Active High)
0
28
I_USEIGN
Send events when IGN changes. Bit 0=Low. Bit 1=High
0
29
I_OUTPUT1
Output 1 Setting. See note at bottom for values
32
30
I_OUTPUT2
Output 2 Setting. See note at bottom for values
32
31
I_OUTPUT3
Output 3 Setting. See note at bottom for values
32
32
I_OUTPOLARITY1
Output 1 polarity (0=Low 1=High)
1
33
I_OUTPOLARITY2
Output 2 polarity (0=Low 1=High)
1
34
I_OUTPOLARITY3
Output 3 polarity (0=Low 1=High)
1